Test Data

Bimax IM Testing Data

315 GSM

Mechanical PropertiesAverage
0° Fiber Direction Tensile Str. (ksi)155
0° Fiber Direction Tensile Mod. (Msi)11.2
0° Fiber Direction Compression Str. (ksi)91
0° Fiber Direction Compression Mod. (Msi)10.3
In-Plane Shear Strength (ksi)18
In-Plane Shear Mod. (Msi)0.7
+/-45 Tensile Strength (ksi) 34
+/-45 Tensile Mod. (Msi) 2.5
+/-45 Compression Str. (ksi) 34
+/-45 Compression Mod. (ksi)2.3

Bimax Heavy Testing Data

350 GSM

Mechanical PropertiesAverage
0° Fiber Direction Tensile Str. (ksi)151
0° Fiber Direction Tensile Mod. (Msi) 9
0° Fiber Direction Compression Str. (ksi)97
0° Fiber Direction Compression Mod. (Msi)8.1
In-Plane Shear Strength (ksi)14
In-Plane Shear Mod. (Msi)0.7
+/-45 Tensile Strength (ksi) 27
+/-45 Tensile Mod. (Msi) 2.1
+/-45 Compression Str. (ksi) 27
+/-45 Compression Mod. (ksi)1.9

QISO Light Testing Data

272 GSM

Mechanical PropertiesAverage
0° Tensile Str. (ksi)107
0° Tensile Mod. (Msi)6.9
90° Tensile Str. (ksi)95
90° Tensile Mod. (Msi)6.5
0° Compressive Strength (ksi)85
0° Compressive Mod. (Msi)6.1
90° Compressive Mod. (Msi)6.1
0° In-plane Shear Str. (ksi)47
0° In-plane Shear Mod. (Msi)2.4

QISO Heavy Testing Data

536 GSM

Mechanical PropertiesAverage
0° Tensile Str. (ksi)119
0° Tensile Mod. (Msi)6.6
90° Tensile Str. (ksi)110
90° Tensile Mod. (Msi)6.7
0° Compressive Strength (ksi)78
0° Compressive Mod. (Msi)6.1
90° Compressive Mod. (Msi)6.3
0° In-plane Shear Str. (ksi)34
0° In-plane Shear Mod. (Msi)2.4