Green Beast Verification

AP1225 – Triaxial Overbraid | CIN1-12252025-025

Layer 1 Verification

Note: This overbraided preform has only ONE layer. Inspection of multilayer preforms will include data for each preform layer and an overall summary, delivering a complete quality package.

Layer 1 Bias Angle

Green Guy StationBias AngleMinimum Bias Angle (Degrees)Maximum Bias Angle (Degrees)
Station 161.5°58°64°
Station 253°50°56°
Station 367.75°65°71°
Station 445°42°48°

Layer 1 Ply Cut Location

Green Guy StationPly Cut Location Pass or FailPly Cut Location MinimumPly Cut Location Maximum
N/AN/AN/A

Layer 1 Thickness

Green Guy StationPly ThicknessTotal Preform Thickness
Station 10.019″0.019″
Station 20.021″0.040″
Station 30.018″0.058″
Station 40.023″0.081″

Layer 1 Defects

Green Guy StationAllowable Defects
ALLNone